Please follow these simple steps to By-Pass your "Bubble-Up" Radon in Water Aeration System



IF WATER WILL NOT FLOW FROM THE TAPS:


First! Check the pressure gauge at the original well pressure tank.

Does the pressure gauge read at or close to 0 psi?

IF YES: The problem is likely with your well's "submersible" pump.
Check the pump's electrical switch or circuit breaker.
Contact your well company.

IF NO:
Check the "Bubble-Up" pump head located on the top of the radon system.

Is the "RED" Failure/Alarm light on?


IF YES, FOLLOW THESE STEPS.

STEP#1: Close ball valve #3
(yellow handle, output from system into house)

STEP#2: PUSH and HOLD system "RESET" button on head for approx. 5 seconds.

Pump should start and run for approx. 10 seconds then shut off.
RED FAILURE LIGHT SHOULD GO OUT!

STEP#3: Open ball valve #3 to feed the house.
(Handle should be in line with copper pipe)


CONGRATULATIONS!

Pump reset is complete,
YOU SHOULD HAVE WATER.

IF THIS PROCEDURE IS NOT SUCCESSFUL:

Locate the HANDLE that reads: BY-PASS / SERVICE at the top of the Bubble-Up system.

Swing the By-Pass valve handle from "SERVICE" to "BY-PASSED" position.
UNPLUG BOTH PLUGS FROM THE WALL RECEPTICAL BEHIND THE SYSTEM.


THE "BUBBLE-UP" SYSTEM IS NOW BY-PASSED!

Please call our office at 1-888-276-0456 to schedule service for your radon unit as soon as possible.